PROLOAD T1/T2
Lightning protector unit
PROLOADT1: Single module for single winch cranes
PROLOADT2: Dual module for twin winch cranes
- Surge voltage protection unit which serves to limit eventual surge voltages in intrinsically safe circuits.
- For installation with the RCI-4000IS and RCI-4100IS systems.
- Type of module: PLUGTRAB PT 4-EX(I)-24DC-ST(DIN rail mounted)
- EC-Type Examination Certificate Number: KEMA 00ATEX1099 X
- Equipment marking: Shall include EEx ia IIC T4...T6
- Ambient temperature range:
- -40°C to +40°C for temperature class T6
- -40°C to +55°C for temperature class T5
- -40°C to +80°C for temperature class T4
- Electrical data:
- Ui = 30
- VIi = 500 mA
- Pi= 3 W
- The effective internal capacitance Ci= 1.1 nF
- The effective internal inductance Li= 1 uH
- Dimensions: 140mm (L) x 140mm (W) x 107mm (D)
- Mounting: Via a mounting bracket (Part Number: KIT4000LP)
- Glands for cable entry: 20mm HEYCO glands
- Weight: 3.8kg (approx) including mounting bracket